1. Water discharge: Adjust the dissolved air flotation machine so that the water level line is about 20-50mm above the sludge tank baffle. The water level line of the air flotation tank can be adjusted using a separate water collector.
2. During the operation period, close all the pressure regulating valves, adjust the rotary switch of household appliances to the fully automatic position, and then run the centrifugal pump. At this time, the air compressor also enters the fully automatic operation state, and then open the water valve, water outlet valve, and pressure regulating valve of the pipeline centrifugal pump in sequence. The working pressure of the Barometer keeps rising, which should generally be 0.4-0.5MPa. At this point, open the water output control valve of the gas tank to release the dissolved water into the air flotation tank according to the safety relief valve. A large number of small bubbles appear in the air flotation tank, making the cold water turn milky white. The air flotation device is normal, and the higher the working pressure of the vessel, the higher the relative density of the released small bubbles in the vessel. The gas in the dissolved air flotation machine is supplied by an air compressor. Because the dissolved water continuously carries the gas from the tank, the gas in the tank decreases day by day and the water level rises. When the water level rises to a certain position, the float Level sensor will operate the air compressor to make the tank full of air.
3. Operation: After the air flotation device operates normally, the wastewater after the dosing reaction is sent to the air flotation machine mixing tank. The total flow rate should first decrease and then increase to the rated current after normal operation.
4. Dissolved water: Dissolved water is first converted back into bank running water using drinking water, and then converted into treated cold water and returned to bank running water. If the amount of waste water used for cleaning is large and there are many foam, which will harm the actual effect of the flotation machine, warm water can be used all the time.
5. After the sludge accumulates to a certain thickness, run the foam scraper.
6. When shutting down the dissolved air flotation machine, it is necessary to first turn off the wastewater pressure regulating valve, then turn off the sewage pump, scrape the foam clean, stop the scraping machine, then open the cold water valve, enter the drinking water for 30 minutes, close the water seepage pressure regulating valve of the air flotation device, and stop the pipeline centrifugal pump.