Treatment of Common Faults of Dissolved Air Floater

1、 Small dissolved air volume:
Check whether the dissolved air releaser and dissolved air pump are blocked and whether the impeller of the dissolved air pump is normal.
2、 No dissolved water:
Check whether the valve is opened, whether the dissolved gas releaser is blocked, whether the compressor operates normally and whether the air supply is insufficient.
3、 Long term non use, shutdown after startup:
The reason for this fault is that the self protecting line has fallen off or the contact resistance of the self protecting line at the point is too large. The self-protection circuit shall be installed and the contact resistance of the self-protection point shall be eliminated.
4、 The dissolved water is normal when the machine is started, and there is no dissolved water after half an hour:
It may be related to the automatic electrical appliance of gas supply. Check whether the manual and automatic change-over switches are in place and whether the automatic control lines fall off.