+86-510-88996388
enLanguage
Home / Knowledge / Details

Jul 21, 2023

Operation process and common problems of air flotation machine

1. Pre startup inspection:
(1) Check that all gate valves of the air flotation machine are in all normal operating conditions;
(2) Check that the water level line of the container tank is in all normal operating conditions;
(3) Verify that the electrical equipment is in all normal operating conditions.
2. Initiation process:
(1) Configure and add coagulants, select drugs, and start the mixing system software;
(2) Start the air compressor, open the bypass valve, and adjust the working pressure of the air inlet to 0.2MPa;
(3) Turn on the container water pump, infiltrate water into the container, adjust the water level line of the container to around 1/3 of the liquid level transmitter of the container. At this time, the working pressure of the container should reach 0.4MPa. After the container inlet pump continues to work normally for 3-10min, the air flotation inlet pump can be started;
(4) Adjust the dosage, inlet water volume, and container water volume based on the transformation of the effluent water body to ensure the effluent water body;
(5) Based on the formation status of sludge, operate the outlet gate valve, adjust the sludge level gauge to the sludge discharge regulations of the scraper, and start the scraper to carry out slag scraping;
(6) After starting the machine, the air flotation water seepage and drainage equipment should be checked to ensure the balance of inlet and outlet water, and ensure that everything in the air flotation is working properly.
3. Shutdown process:
(1) Turn off the scraper;
(2) Turn off the air flotation inlet pump.
4. Frequently asked questions:
(1) Once the container level gauge is adjusted, it should be maintained and should not be adjusted frequently;
(2) Adjust the dosage, inlet water volume, and container water volume immediately based on the effluent water body;
(3) Add lubricating grease to each rolling bearing, transmission chain, sprocket chain, transmission gear, gear rack, and slide rail on time (under ten days), and carry out maintenance every three months.
What causes poor air flotation performance?
1. The release device is blocked, causing large bubbles to appear in the contact area of the air flotation, causing the air flotation and impact on the scum, causing the scum to lose stability and resulting in turbid production water.
2. Insufficient dosage of chemicals or excessive inflow of water.
3. The air flotation reflux ratio is insufficient, which refers to the ratio of treated water to dissolved water.
4. When the air flotation machine scrapes the slag, the movement speed is too fast, causing the lower layer of scum to be sheared and broken, and turbulent flow to emerge with the water. Of course, if the slag is not scraped in time and there is too much mud accumulation at the bottom, the air flotation effect will also be poor.