1. When the water filling time of the air flotation machine is too long, causing the temperature of the water in the sedimentation area of the mud pipe to drop, and the temperature gap between the temperature of the sedimentation water and the seepage water is too large, it is easy to produce a tropospheric situation caused by the water temperature difference, causing the flocculation to fail. It is easy to move down, thus affecting the processing effect. Therefore, the shutdown frequency and shutdown time should be minimized. If the above situation occurs, you can drain as much of the water in the equipment through the mud valve, so that the troposphere conditions will quickly subside;
2. If the surface of the sludge in the contact area is uneven, with large bubbles appearing in some areas or the water flow is unstable, a release device should be used to clear the blockage; in the separation area, the surface of the sludge is uneven, and large bubbles generally burst on the water surface, indicating that the bubbles are in contact with the coagulant. The adhesion is not very good, so the concrete system needs to be adjusted. However, the water output is turned off and returned to the sump. When the water output reaches the standard, the subsequent work process can be entered;
3. Operate the water output adjustment tube of the air flotation machine to keep the air flotation water level 5-10cm below the scraping slot hole. After the water level is restored, use a steam flow meter, smart water meter, etc. to accurately measure the water flow until the rated flow is reached. Only then;
4. Check the increase of pressurized floc in the air flotation tank and the accumulation of sludge through the water surface. When the accumulation reaches 5-8cm, start the sludge thickener to scrape the sludge. Check whether the slag can be scraped and cleaned, whether the slag overflow is uniform, whether there are difficulties with the fluidity of the slag, whether the scraping rate is appropriate, whether the treatment effect is affected, etc.
5. If there are many large bubbles or milky white bubbles during the operation of the air flotation machine, check the water level of the dissolving tank to see if there is any problem with the water level. If the water level is normal, it is likely that the wool gas safety relief valve is blocked. At this time, the problem can be solved by adding water, disassembling the safety relief valve, cleaning and reinstalling it.
May 17, 2024
How to deal with common faults that occur during the use of air flotation machines?